• Promotions
  • Finance
  • Careers
  • Customer Portal
  • Locations
  • Order Parts
  • Blog
MS series

FOR THE ULTIMATE RELIABILITY AND PRECISION

When your project demands measurement without compromise, turn to the MS AX motorized total station for guaranteed performance.


Features

  • Angular accuracy option of either 0.5” or 1”

  • Reliable distance accuracy at 0.5 mm

  • Auto-collimation accuracy of 1”

  • Automated Matrix Detection and Target Acquisition

  • Rapid and customizable 2D monitoring

Specifications

1 Prism:
MS1AX: 1mm + 1ppm
1 Prism:
MS05AX: 0.8mm + 1ppm
1 Prism:
3,500m for both
Accuracy*:
MS1AXII: 1” (0.3mgon*)
Accuracy*:
MS05AXII: 0.5” (0.15mgon*)
Ingress Protection:
IP-64
Minimum Reading:
MS1AX: 0.1mm / 1mm
Minimum Reading:
MS05AX: 0.1" (0.02 mgon)
Minimum Reading:
MS1AX: 0.5"( 0.1 mgon)
Minimum Reading:
MS05AX: 0.01mm / 0.1mm
Non-Prism Mode:
MS05AX: 1mm + 1ppm
Non-Prism Mode:
MS1AX: 400m
Non-Prism Mode:
MS1AX: 2mm + 1ppm up to 200m
Non-Prism Mode:
MS05AX: 100m
Operating Temperature:
-10 to +50 ºC
Reflective Sheet:
MS05AX: 200m
Reflective Sheet:
MS1AX: 300m
Reflective Sheet:
MS05AX: 0.5mm + 1ppm
Storage Temperature:
-30 to +70 ºC

Applications

  • Geospatial Monitoring 
  • Civil Engineering & Design 
  • Utilities 
  • Mining 
  • Monitoring 

Overview

WHEN THERE'S NO MARGIN FOR ERROR

Major civil engineering tasks often demand the highest possible accuracy and reliability, and the MS total station series will surpass your expectations. A solution for the ultra-precise measurement of dimensions and geometry, the MS series was designed to meet the needs of manufacturing, service, and maintenance. Set your expectations high when accuracy is paramount for projects that must monitor displacement and deformation.

  • Features

    Features

    • Angular accuracy option of either 0.5” or 1”

    • Reliable distance accuracy at 0.5 mm

    • Auto-collimation accuracy of 1”

    • Automated Matrix Detection and Target Acquisition

    • Rapid and customizable 2D monitoring

  • Specifications

    Specifications

    1 Prism:
    MS1AX: 1mm + 1ppm
    1 Prism:
    MS05AX: 0.8mm + 1ppm
    1 Prism:
    3,500m for both
    Accuracy*:
    MS1AXII: 1” (0.3mgon*)
    Accuracy*:
    MS05AXII: 0.5” (0.15mgon*)
    Ingress Protection:
    IP-64
    Minimum Reading:
    MS1AX: 0.1mm / 1mm
    Minimum Reading:
    MS05AX: 0.1" (0.02 mgon)
    Minimum Reading:
    MS1AX: 0.5"( 0.1 mgon)
    Minimum Reading:
    MS05AX: 0.01mm / 0.1mm
    Non-Prism Mode:
    MS05AX: 1mm + 1ppm
    Non-Prism Mode:
    MS1AX: 400m
    Non-Prism Mode:
    MS1AX: 2mm + 1ppm up to 200m
    Non-Prism Mode:
    MS05AX: 100m
    Operating Temperature:
    -10 to +50 ºC
    Reflective Sheet:
    MS05AX: 200m
    Reflective Sheet:
    MS1AX: 300m
    Reflective Sheet:
    MS05AX: 0.5mm + 1ppm
    Storage Temperature:
    -30 to +70 ºC
  • Downloads & Documentation
  • Details

    Applications

    • Geospatial Monitoring 
    • Civil Engineering & Design 
    • Utilities 
    • Mining 
    • Monitoring 

    Overview

    WHEN THERE'S NO MARGIN FOR ERROR

    Major civil engineering tasks often demand the highest possible accuracy and reliability, and the MS total station series will surpass your expectations. A solution for the ultra-precise measurement of dimensions and geometry, the MS series was designed to meet the needs of manufacturing, service, and maintenance. Set your expectations high when accuracy is paramount for projects that must monitor displacement and deformation.

Contact

Contact

Consignment

Request a Service

×

Coastline Equipment Employee Portal

×

Your session will expire in . If you want to reset this timer, please click OK.

Change Your Preferred Location